<th id="d8qez"></th>

  • <object id="d8qez"><tt id="d8qez"></tt></object>
    <samp id="d8qez"></samp>
    <pre id="d8qez"><nav id="d8qez"></nav></pre>

        1. <span id="d8qez"><kbd id="d8qez"></kbd></span>

            1. <optgroup id="d8qez"></optgroup>

                  <delect id="d8qez"></delect>
                      <th id="d8qez"></th>

                        <object id="d8qez"><form id="d8qez"></form></object>
                        <th id="d8qez"><menu id="d8qez"><output id="d8qez"></output></menu></th>

                              <code id="d8qez"><b id="d8qez"></b></code>
                              1. <optgroup id="d8qez"><b id="d8qez"></b></optgroup>
                                <optgroup id="d8qez"><mark id="d8qez"></mark></optgroup>
                                <code id="d8qez"><sup id="d8qez"></sup></code><progress id="d8qez"></progress>

                                1. <th id="d8qez"><xmp id="d8qez"><object id="d8qez"></object></xmp></th>
                                  <code id="d8qez"><tt id="d8qez"></tt></code><code id="d8qez"><ol id="d8qez"></ol></code>
                                2. 您好!歡迎光臨共立消防科技(廣東)有限公司,我們竭誠為您提供金牌服務!

                                  專注消防維保檢測

                                  打造消防服務行業領軍品牌

                                  消防檢測維保服務咨詢熱線:

                                  15322445327

                                  一、試驗方法

                                  1.外觀、外部結構及總質量檢查

                                  1.1 用目測方法觀察滅火器外表面和外部結構。

                                  1.2 用秤稱出滅火器的總質量。稱重儀的誤差不應大于被測滅火器額定充裝量的5%‰。

                                  2.滅火器氣密性試驗

                                  2.1 對二氧化碳滅火器和貯氣瓶,卸除噴射軟管組件或車架等附件,將已充裝滅火劑的滅火器氣瓶或已充裝驅動氣體的貯氣瓶浸沒在55-℃的清水槽中,保持30min,并注意觀察。

                                  2.2 對貯壓式滅火器,卸除噴射軟管組件及車架等附件,將已充裝滅火劑的滅火器氣瓶(筒體)浸沒在水溫不低于5℃的清水槽中,保持30min,并注意觀察。

                                  3.20℃噴射性能試驗

                                        手提式滅火器按GB 4351.1規定的試驗方法進行;推車式滅火器按GB 8109規定的試驗方法進行。

                                  4.使用溫度噴射性能試驗

                                        手提式滅火器按GB 4351.1規定的試驗方法進行;推車式滅火器按GB 8109規定的試驗方法進行。

                                  5.操作機構檢查

                                        手提式滅火器按GB4351.1規定的試驗方法進行;推車式滅火器按GB8109規定的試驗方法進行。

                                  6.滅火劑充裝量檢查

                                  6.1 先稱出滅火器的總質量,泄壓(回收氣體類滅火劑),確認滅火器內部無壓力時,卸下器頭和部件,清除滅火劑,再復原裝上器頭和部件,稱出滅火器的空質量,將滅火器的總質量減去滅火器的空質量,即為滅火劑充裝量。

                                  6.2 維修工序中的滅火劑充裝量檢查可采用復稱的方法進行,復稱用的秤的準確度應不低于灌裝設備的計量準確度。

                                  7.內部結構和內部腐蝕檢查

                                        用目測方法觀察滅火器氣瓶(筒體)內表面和內部結構。

                                  8.水壓試驗

                                  8.1 手提式滅火器氣瓶(筒體、貯氣瓶)、器頭(閥門)的水壓試驗按GB4351.1規定的試驗方法進行。

                                  8.2 推車式滅火器氣瓶(筒體、貯氣瓶)的水壓試驗按GB5099或GB5100規定的試驗方法進行。

                                  8.3 推車式滅火器器頭、閥門和瓶口的水壓試驗按GB 8109規定的試驗方法進行。

                                  8.4 二氧化碳滅火器鋼瓶殘余變形率的測定按GB/T 9251規定的試驗方法進行。

                                  9.噴射軟管組件水壓試驗

                                        手提式滅火器按GB4351.1規定的試驗方法進行;推車式滅火器按GB8109規定的試驗方法進行。

                                  10.滅火劑質量檢查

                                        滅火劑的質量檢查,應按相關國家標準或行業標準規定的方法進行項目抽檢。

                                  11.壓力指示器示值誤差檢驗

                                  11.1 指示器示值誤差檢驗采用與標準壓力表比對的方法進行,比對用標準壓力表精度不低于0.25級,最大量程應為被測指示器最大量程的1.3倍~1.6倍。檢驗的環境溫度為20℃±5℃,加壓介質為氮氣或壓縮空氣。

                                  11.2 指示器示值誤差檢驗點:零位、工作壓力、工作壓力范圍的上、下限和最大量程。

                                  11.3 示值誤差檢驗時,由零位均勻平穩增壓,經各檢驗點,直至該指示器示值的最大量程,然后以同樣的方式減壓,經各檢驗點,直至零位,在減壓的過程中記錄下各檢驗點的標準壓力表的讀數,以及壓力指示器指針的移動情況。

                                  二、檢驗規則

                                  1.檢驗分類

                                        滅火器維修檢驗分為維修出廠檢驗和維修確認檢驗。

                                  2.維修出廠檢驗

                                  2.1 維修過的滅火器經檢驗合格后方可加貼維修合格證。

                                  2.2 維修出廠檢驗應逐具進行,檢驗項目應按表1規定,并保持檢驗記錄。

                                  表1 滅火器維修檢驗項目

                                  序號

                                  檢驗項目

                                  維修確認檢驗

                                  維修出廠檢驗

                                  檢驗方法

                                  樣本數

                                  抽檢

                                  逐具檢驗

                                  1

                                  外觀、外部結構及總質量檢查

                                  4/2

                                  ?

                                  ?

                                  8.1

                                  2

                                  滅火器氣密性試驗

                                  2

                                  ?

                                  ?

                                  8.2

                                  3

                                  20℃噴射性能試驗

                                  (2)

                                  -

                                  8.3

                                  4

                                  使用溫度噴射性能試驗

                                  (4/2)

                                  ?

                                  -

                                  8.4

                                  5

                                  操作機構檢查

                                  (2)

                                  ?

                                  -

                                  8.5

                                  6

                                  滅火劑充裝量檢查

                                  (2)

                                  ?

                                  ?

                                  8.6.1、8.6.2

                                  7

                                  內部結構和內部腐蝕檢查

                                  (2)

                                  ?

                                  -

                                  8.7

                                  8

                                  水壓試驗

                                  (2)

                                  ?

                                  ?

                                  8.8

                                  9

                                  噴射軟管組件水壓試驗

                                  (2)

                                  ?

                                  ?

                                  8.9

                                  10

                                  滅火劑質量檢查

                                  1

                                  ?

                                  -

                                  8.10

                                  注1:“?”表示進行該項試驗,“一”表示不進行該項試驗。

                                  注2:維修確認檢驗中帶括號樣本數可用序號1和2檢驗后的樣本進行。

                                  注3:序號1和4的樣本數中的4代表4具手提式滅火器,2代表2具推車式滅火器。

                                  注4:維修出廠檢驗中序號6、8和9的檢驗項目可用工序中的逐具檢驗結果進行確認。

                                  2.3 在檢驗中存在表2所列不合格項的滅火器應進行返工或報廢,返工后的滅火器應再按表1規定重新進行檢驗。

                                  表2 滅火器維修檢驗的不合格項

                                  序號

                                  檢驗項目

                                  不合格項

                                  1

                                  外觀、外部結構及總質量檢查

                                  a)符合7.1、7.2報廢要求的未報廢;

                                  b)應更換的零部件未更換,或更換的零部件與原滅火器生產企業提供的零部件的特性不一致;

                                  c)未安裝保險裝置:

                                  d)未加貼維修合格證;

                                  e)維修合格證內容不完整或錯誤;

                                  f)外表面補加涂層不符合6.6.4要求;

                                  g)壓力指示器指針不在綠色工作區域內;

                                  h)滅火器總質量不符合原滅火器生產企業提供的誤差要求

                                  2

                                  滅火器氣密性試驗

                                  a)未按6.7.12的要求進行氣密性試驗;

                                  b)或氣密性試驗后不符合6.7.12的要求

                                  3

                                  20℃噴射性能試驗

                                  a) 不噴射;

                                  b) 有效噴射時間小于標準規定值;

                                  c) 噴射滯后時間超出標準規定值;

                                  d) 噴射剩余率大于標準規定值

                                  4

                                  使用溫度噴射性能試驗

                                  a)不噴射;

                                  b) 有效噴射時間的偏差大于20℃噴射時的有效噴射時間的士50%;

                                  c) 噴射滯后時間超出標準規定值;

                                  d)噴射剩余率大于標準規定值

                                  5

                                  操作機構檢查

                                  a) 保險解脫力不符合標準規定值;

                                  b)開啟力大于標準規定值

                                  6

                                  滅火劑充裝量檢查

                                  滅火劑的充裝量誤差超出GB 4351.1和GB 8109規定的充裝誤差范圍

                                  7

                                  內部結構和內部腐蝕檢查

                                  a)符合7.2報廢要求未報廢;

                                  b)應更換的零部件未更換,或更換的零部件與原滅火器生產企業提供的零部件的特性不一致

                                  8

                                  水壓試驗

                                  a)未按6.5.1的要求進行水壓試驗;

                                  b)水壓試驗后不符合6.5.2的要求;

                                  c) 應更換的零部件未更換,或更換的零部件與原滅火器生產企業提供的零部件的特性不一致

                                  9

                                  噴射軟管組件水壓試驗

                                  a)未按6.5.1的要求進行水壓試驗;

                                  b)水壓試驗后不符合6.5.2的要求;

                                  c)應更換的零部件未更換,或更換的零部件與原滅火器生產企業提供的零部件的特性不一致

                                  10

                                  滅火劑質量檢查

                                  a) 應更換的滅火劑未更換;

                                  b) 再充裝的滅火劑不符合6.7.3的要求

                                  3. 維修確認檢驗

                                  3.1 維修機構每年應至少進行1次維修確認檢驗,并保持檢驗記錄。

                                  3.2 維修機構有下列情況之一,應進行維修確認檢驗:

                                        a)首批維修產品;

                                        b)暫停滅火器維修半年以上,恢復維修時;

                                        c)維修工藝發生重大變化時。

                                  3.3 維修確認檢驗的樣本應在經維修出廠檢驗合格的產品中抽取,檢驗項目和樣本數按表1的規定。維修確認檢驗的抽樣基數:手提式滅火器應不少于15具,推車式滅火器應不少于5具。

                                  3.4 檢驗中存在表2所列不合格項的,應判維修確認檢驗不符合。


                                  佛山共立消防專業提供滅火器檢測服務。

                                  聯系我們
                                  共立消防
                                  客服QQ:48545242
                                  服務熱線:15322445327
                                  售后服務:15322445327
                                  電子郵件:48545242@qq.com
                                  公司地址:佛山市三水區樂平鎮西樂大道東7號金四季商貿美食城H座二層
                                  国产在线观看高清视频黄网_精品人妻人人做人人爽夜夜爽_久久精品人妻一区二区三区_亚洲av免费观看在新更新 国产精品有码无码AV在线播放_成人做受视频试看120秒_开会时老板不让穿内裤随时做_翁公和在厨房猛烈进出 久久久久亚洲精品无码系列_chinasex喷白浆videos自慰_中文无码VR最新无码AV专区_国产美女视频免费观看的网站 无码免费一区二区三区_国产高清特黄无遮挡大片_91精品久久综合熟女_日本乱偷中文字幕视频 日韩人妻高清精品专区_亚洲色大成网站WWW永久男同_野花在线观看免费观看高清_中文字幕无码亚洲一本大道在线 国产免费黄色视频_中文字幕乱偷av_久久国产高潮流白浆免费观看久久_久久久91人妻无码精品蜜桃HD